System Imaging Function:
|
1)Color Doppler Enhancement Technology
2)Two-dimensional grayscale imaging
3)Power Doppler imaging
4)PHI pulse inverse phase tissue harmonic imaging + frequency composite technique
5)With the working mode of spatial composite imaging
6)Linear array probe independent deflection imaging technique
7)Linear trapezoidal spread imaging
8)B/Color/PW trisynchronous technology
9)Multibeam parallel processing
10)Speckle noise suppression technology
11)Convex expansion imaging
12)B-mode image enhancement technique
13)Logiqview
|
Measurement and analysis:
|
1)General measurement: Including distance, area, circumference, volume, area ratio, distance ratio, Angle, S/D velocity, time,
heart rate, acceleration, etc 2)Obstetrics: Obstetrics supports the measurement of fetal data ≥3 fetals, including fetal weight algorithm, growth curve display, fetal echocardiography measurement (including left ventricular function measurement, left ventricular myocardial weight, etc.); Fetal measurement OB1, OB2, OB3) 3)Blood flow measurement, sampling volume at least 8 levels adjustable 4)Automatic measurement of endovascular media 5)All measurement data Windows are removable 6)Customized comments: Include insert, edit, save, etc |
Input/output signal:
|
Input: Mquipped with digital signal interface.
Output: VGA, s-video,USB, audio interface, network interface.
|
Connectivity:
|
Medical digital imaging and communications DICOM3.0 interface components.
|
Support network real-time transmission:
|
can real-time transmission of user data to the server.
|
Image management and recording device:
|
500G hard disk Ultrasonic image archiving and medical record management function: complete the storage management and playback storage of patient static image and dynamic image in the host computer
|
General system function:
|
1)PC Platform
2)Color monitor: 15 "high resolution color LCD monitor 3)Probe interface: zero force metal body connector, effectively activated two mutual common interfaces 4)Dual power supply system, built-in large capacity lithium battery, battery power 2 hours duration, and the screen provides power display information
5)Net Weight: 4.5kg
6)Support quick switch function, cold start 39 seconds. 7)Main interface miniatures 8)Full-screen Chinese and English annotation input, Chinese input method 2 kinds, including wubi input method 9)Built-in patient data management station 10)Customized comments: include insert, edit, save, etc |
Probe Specifications:
|
1)2.0-10MHz V¬ariable frequency, frequency range 2.0-10MHz
2)Optional Probes: Convex, Linear, Transvaginal, Phased Array, Microconvex 3)5 kinds of frequencies of each probe, variable fundamental and harmonic frequency 4)Abdomen: 2.5-6.0MHz 5)Superficial:5.0-10MHz 6)Cardiac:2.0-3.5MHz 7)Puncture Guidance: probe puncture guide is optional, puncture line and Angle are adjustable 8)Transvaginal: 5.0-9MHZ 9)B/D Dual-purpose: Linear: B/PW, Convex: B/PW, Sector-Scan: B/PW, Phased Array: B/PW |
Main parameters of two-dimensional grayscale imaging:
|
1)Imaging modes including: B Mode, 2B Mode, 4B Mode, M Mode, Color(Color Doppler) Mode, PDI(Power Doppler) Mode, PW Mode, CW
Mode,Dissection M, B+C+PW three modes, B+PDI+PW three modes, support single window display, double window real-time display, four windows display 2)Imaging speed: the maximum frame speed is 80 frames per second 3)Beam focus: 4 focal points 4)Real-time amplification (unlimited) and freeze amplification (3 times) 5)2D image gain, continuously adjustable 6)Receiving mode: parallel processing of multi-beam signals 7)The sound power is adjustable by sight 8)Scanning Depth(mm)≥351mm 9)Support Kidney Stone breaking line 10)Sound beamformer: digital sound beamformer, digital full-range dynamic focusing, digital dynamic variable aperture and dynamic trace, and focus position can be adjusted in the whole imaging area 11)Playback: image playback for 48 seconds (Phased Array B mode) 12)False color 7 kinds of color 13)Preset conditions: for different inspection organs, preset the optimal image inspection conditions, reduce the adjustment during operation, and commonly required external adjustment and combination adjustment 14)segment adjustment for 8 segments 15)Sector Scan Angle: 4 grades adjustabl 16)TEI Index
17)2D Modes(B) Phased Array: maximum: ≥6898 frames, Color,PDI maximum: ≥4050 frames
|
Spectral Doppler technique requirements:
|
1)Transmission Mode: pulse wave doppler PW, continuous wave doppler CW
2)PW testing range 0~7.5m/s 3)Doppler Frequency: PW frequency 4)Maximum measured velocity: positive or reverse flow velocity of 7.5m/s 5)Doppler Automatic envelope measurement and calculation 6)SV sampling width and location range : width 1-8mm 7)Display Control: reverse display (left/right;Up/down) 8)PW Real-time automatic measurement function 8)Scaleplate ≥16 grades; PRF 0.7kHz-9.3KHz adjustable 10)Playback: automatic playback of movies |
Color Doppler technique requirements:
|
1)The doppler gain is continuously adjustable
2)Color enhancement
3)B+COLOR display on both left and right sides of the same screen 4)Color mode baseline adjustment ±15 grades |
Rich data interface for data analysis:
|
1)VGA interface
2)Printing interface
3)Network interface 4)SVIDEO interface 5)Foot switch interface |