4 Inch Touch Screen Human Use Portable SpO2 Pr Monitor

Product Details
Customization: Available
Customized: Customized
Certification: CE, FDA, EEC, ISO13485
Gold Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

  • 4 Inch Touch Screen Human Use Portable SpO2 Pr Monitor
  • 4 Inch Touch Screen Human Use Portable SpO2 Pr Monitor
  • 4 Inch Touch Screen Human Use Portable SpO2 Pr Monitor
  • 4 Inch Touch Screen Human Use Portable SpO2 Pr Monitor
  • 4 Inch Touch Screen Human Use Portable SpO2 Pr Monitor
  • 4 Inch Touch Screen Human Use Portable SpO2 Pr Monitor
Find Similar Products

Basic Info.

Model NO.
RGW-Z0883
Type
Health Care Intercom System
Brand Name
Rgw
Quality
High Quality
After-Sale Service
Online Technical Support
Warranty Year
3 Years
Place of Origin
Shanghai, China
Instrument Classification
Class II
Safety Standard
GB/T18830-2009
Transport Package
Carton Box
Specification
N/M
Trademark
RGW
Origin
China
Production Capacity
10000PCS/Month

Product Description

4 Inch Touch Screen Human Use Portable SpO2 Pr Monitor4 Inch Touch Screen Human Use Portable SpO2 Pr Monitor4 Inch Touch Screen Human Use Portable SpO2 Pr Monitor4 Inch Touch Screen Human Use Portable SpO2 Pr Monitor4 Inch Touch Screen Human Use Portable SpO2 Pr Monitor

parameter:

The overall medical white color is novel and generous
Physical button (machine side switch button, one-button pressure
measurement button) + touch button
4 inch TP fit touch screen
Sound and light alarm, more convenient for doctors to observe the
patient's status
Built-in 3.7V 2000mAh polymer lithium battery
Humanized charging base
Support contact and TYPE-C charging
Waterproof rating: IPX2
Host size: 155*72.5*28.6
Support Chinese and English

Technical parameters of blood oxygen pulse rate:
Blood oxygen saturation
Blood oxygen saturation measurement range: 0%~100%
Blood oxygen saturation display resolution: 1%
The accuracy of blood oxygen saturation measurement: in the
range of 70% ~100%, the measurement error should be ±4%; in the
range of 0% ~ 69%, the measurement error is not defined.
Blood oxygen saturation alarm setting range: the upper limit of the
alarm should be 1%~100%; the lower limit of the alarm should be
0%~99%
Blood oxygen saturation alarm accuracy: the alarm accuracy should
not exceed ± 1% of the alarm setting value.
Technical alarm: there should be an alarm when the sensor falls off Pulse rate:
The pulse rate detection range should be 30bpm~240bpm
Pulse rate detection resolution: 1bpm;
The accuracy of pulse rate measurement should be ±3bpm;
Pulse rate alarm setting range: the upper limit of the alarm
should be 2bpm-254bpm;
The lower alarm limit should be
0bpm-252bpm
Pulse rate alarm accuracy: the alarm accuracy should not
exceed the set value ± 1bpm.

Built-in side stream CO2 technical parameters:
Sensor type: side stream CO2
Sampling flow: 50 -150ml/min; default 75ml/min
Technical principle: dual-wavelength non-dispersive infrared
(NDIR), no moving parts
Initialization time: display the waveform within 3 seconds, reach the
index requirement within 5 minutes (at 25°C room temperature)
Carbon dioxide range: 0 - 114 mmHg, 0 - 15 %, 0 - 15.2 kPa Rise
time: less than 4s
Carbon dioxide resolution:0.1mmHg 0 - 38 mmHg
0.25 mmHg 39 - 114mmHg
Carbon dioxide accuracy: 0 - 40mmHg ±2 mmHg
41 - 76 mmHg ±5% of reading
77 - 114 mmHg ±8% of reading
Respiration rate greater than 80 BPM ±12% of reading
Carbon dioxide stability: short-term drift: less than 1 mmHg within 4
hours
Long-term drift: meet the measurement accuracy requirements
within 120 hours
Data sampling rate: 100 Hz
Respiration rate range: 3-120 times/min
Respiration rate accuracy: ±1 times/minute
Compensation: Atmospheric pressure range: 400 mmHg-800 mmHg
(automatic compensation)
Calibration: The user does not need to calibrate regularly.
Voltage requirements: 5.0 VDC ±5%, 2W
Power consumption: 1.0W (typical value); 1.8W maximum
(warm-up)
Data interface: RS232, 19200 baud rate, Standard N-8-1
Data output: carbon dioxide concentration curve, end-tidal carbon
dioxide concentration, inhaled carbon dioxide concentration,
respiration rate. (The host is equipped with a mixed gas type, and
the measurement result is the compensated value)
The design follows the standard: 60601-1
80601-2-55 (ISO21647)

 

 