Technical Specifications
|
||
Model
|
FCA800
|
FCA600
|
Assay types
|
Random access
|
|
Throughput
|
960 Thr(include ISE), 800 T/Hr(biochemical test only) |
760 Thr(include ISE), 600 THr(biochemical test only) |
Analytical methods
|
End point, Kinetic(Rate), Fixed time, Single standard, Multi-standard, Single wavelength assay, Bichromatic, Bi-reagent assay, Serum blank assay, Immunoturbidimetric assay and ISE assay (KNa\Ca\CAPH)
|
|
Sample capacity
|
2 x 92 primary tube or micro serum cup
|
1 x 92 primary tube or micro serum cup
|
Sample/reagent probe
|
With liquid level sensor, automatically checking and tracking reagent allowance ability, internal and external nano treated, stereoscopic collision protection, plugging probe checking ability
|
|
Sample volume
|
1.0- 100μL in 0.1 μL/step
|
|
Reagent volume
|
1-500μL in 0.1 μL/step
|
|
Reagent tray
|
2 reagent trayes, barcode scaner available (on request), R3/R4 assay models available
|
|
Reagent refrigerater
|
2-8ºC, 24 hrs available
|
|
Reading Cuvette
|
160 cuvettes, made of ultraviolet transmitable plastic(or quartz glass cuvettes available on request)
|
|
Reaction volume
|
Minimum 120 μl
|
|
Reaction disc temp.
|
Water bath system, 37 0.1"C,(air bath on request)
|
|
Cuvette cleaning
|
Automatical warm water washing station with 8 channels, blank reading for ensuring each cuvette well cleaned before using. Smart detergent clean for high contamination cuvette and probe, efficiently decreasing carry-over
|
|
Carry-over
|
Less than 0.05%
|
|
Monochromator
|
Concave grating
|
|
Wavelength range
|
340-810nm
|
|
Alarm
|
Automatic alarm for lack of reagent, sample,water, or waste filled and other errors, showing the info on monitor
|
|
Mixer
|
2 nano-surface treated mixing probers, with automatic warm water washing station for each one
|
|
Quality control
|
Multi-level QC for the same item automatically monitoring and alarming if the results out of control
|
|
Assay Linearity range
|
Wide linearity range measuring, also with automatically diluting function for high value sample
|
|
Calibration
|
Single or multi-points calibration, supporting linear and nonlinear assay
|
|
Data processing
|
Powerful software for calculating, blanking, multi-analysis, data reviewing, QC and results management, on line monitoring, editing etc.
|
|
Data storage
|
Long-term storage, storage capacity upon PC hard disc
|
|
Print
|
Multi report formats and user-self- defined report format are available
|
|
Power supply
|
AC 110V/60Hz or 220V/50Hz
|
|
Dimensions
|
1200mm x 900mm x 1100mm
|