Customization: | Available |
---|---|
Brand Name: | Rgw |
Quality: | High Quality |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Material characteristics:
1. The face of the simulated person can be used for years without replacement. Face skin, neck skin, chest skin, and hair are made of imported thermoplastic elastomer mixed rubber materials.
2. They are made of stainless steel molds and high-temperature injection molding machine.
3. They have correct anatomical marks, real feel, uniform skin color, realistic shape and appearance. Durable, non-deformed when disinfected and cleaned, and easy to disassemble and replace.
CPR simulator function:
1. The joints of the simulated human upper limbs can move freely.
Wireless connection between the simulated human and the tablet computer.
2. Simulated vital signs:
1) In the initial state, the simulated human pupils are dilated and the carotid artery is not pulsating.
2) During the compression process, the passive pulsation of the human carotid artery is simulated, and the pulsation frequency is consistent with the compression frequency.
3) After the rescue is successful, the simulated human pupil returns to normal and the carotid artery beats spontaneously.
3. Standard airway opening is possible.
4. Perform manual chest compression and artificial respiration.
5. Three modes of operation:
1) Method 1: CPR training, in the set time range, you can press and blow.
2) Method 2: Mode assessment, within the set time frame, according to the 2015 International Cardiopulmonary Resuscitation Standard, the ratio of pressing and blowing is 30:2, and 5 cycles are completed.
3) Method 3: Actual combat assessment, within the set time frame, according to the 2015 International Cardiopulmonary Resuscitation Standard, the ratio of pressing and blowing is 30:2 to complete 5 cycles of operations.
NOTE: Evaluation process: In addition to the realization of CPR operation, the steps of the evaluation process can be: emergency call; consciousness discrimination; pulse discrimination; breathing discrimination; removal of foreign bodies in the mouth.
CPR display function:
6. Electronic monitoring: electronically monitor the airway opening and compression positions, and display the correct and incorrect times of artificial respiration and extracardiac compression.
7. Voice prompt: full Voice prompt, adjustable volume.
8. The bar code shows the blowing volume: the correct blowing volume is 500/600ml-1000ml.
9. The bar code shows the pressing depth, try to press more than 5cm correctly.
10. The operating time can be set.
11. Power status: built-in lithium battery, matching charger
Printer function:
1. You can choose to print the operation process after the operation is over.
2. The content of the transcript covers the operation method, the number of presses and blows in each cycle operation, the correct/wrong number of presses, the reason and number of wrong presses, the correct/wrong and the number of blows, the cause and number of wrong blows, and the setting Set time, operation time and performance evaluation.
Standard Configuration:
1. An advanced CPR simulator;
2. Tablet;
3. A hand-push type portable hard plastic box;
4. A resuscitation operation pad;
5. One box of disposable disinfection mask (50 sheets/box);
6. One piece of dough can be replaced;
7. Five lung airbags can be changed;
8. manual