Features
1)Be applicable for NIBP and SpO2 monitoring of adult, pediatric and neonate of all ages, easy to operate, high cost-effective;
2)Be applicable for medicine, surgery, operating room, ICU/CCU, emergency room, obstetrics and gynecology, pediatrics;
3)Compact and flexible appearance, easy for carrying and suitable for indoor and outdoor (in ambulance) monitoring;
4)Built-in rechargeable lithium polymer battery, ensuring uninterrupted monitoring;
5)Perfect menu design, user-friendly interface;
6)Display the measurement result of SYS, DIA, MAP, SpO2, PR and bar graph by the display screen of high-brightness digital tube;
7)2.8'' (320×240) true color TFT LCD screen, displays the information of time, SpO2 Plethysmogram, alarm condition, trend graph,
list and system settings, etc.;
8)Visual and audible alarm for SYS, DIA, MAP, SpO2 and PR, and upper and lower limit of alarm can be set as necessary;
9)Independent nonvolatile memory, storage for up to 2,000 groups of NIBP data and 78,000 groups of SpO2 data;
10)Convenient and quick in reviewing measurement data, available for reviewing the NIBP trend graph of 24 hours and SpO2 trend
graph of 22 hours.
Performance
1 NIBP
Using Oscillometry technology, also called Oscillography technology to measure the blood pressure.
1)Measurement mode: manual/auto/continuous
2)Measurement interval in auto mode: 1, 2, 3, 4, 5, 5×n(n=2, 3, 4...51) min.
3)Resolution: 1 mmHg
4)Accuracy: max mean error: ±5 mmHg; max standard deviation: 8 mmHg.
5)Overpressure protection: dual protection for both software and hardware
6)Others: reset, self-testing and accuracy testing of static pressure
7)Measurement range:
Adult
SYS 40 mmHg~270 mmHg
MAP 20 mmHg~235 mmHg
DIA 10 mmHg~215 mmHg
Pediatric:
SYS 40 mmHg~200 mmHg
MAP 20 mmHg~165 mmHg
DIA 10 mmHg~150 mmHg
Neonate:
SYS 40 mmHg~135 mmHg
MAP 20 mmHg~110 mmHg
DIA 10 mmHg~100 mmHg
2 SpO2
Using Photoelectric Oxyhemoglobin Inspection Technology combined with Capacity Pulse Scanning & Recording Technology to measure
the saturation of blood oxygen.
1)Measurement range: 0 %~100 %
2)Alarm range: 0 %~100 %
3)Resolution: 1 %
4)Accuracy: 70 %~100 %, ±2 %; below 70 % unspecified.
3 PR
Using Photoelectric Oxyhemoglobin Inspection Technology combined with Capacity Pulse Scanning & Recording Technology to measure
the pulse rate.
1)Measurement range: 25 bpm~250 bpm
2)Alarm range: 25 bpm~250 bpm
3)Resolution: 1 bpm
4)Accuracy: ±2 bpm or ±2 %, whichever is greater
4 Safety and Power supply
1)Power supply: rated voltage: ~220 V, rated power: 50 Hz
2)Safety classification: Class I equipment, type BF defibrillation-proof applied part
Accessories
1)User Manual 1pc
2)Power cord 1pc
3)Power adapter 1pc
4)SpO2 sensor 1pc
5)Adult NIBP cuff 1pc
6)NIBP extension tube 1pc