Customization: | Available |
---|---|
Customized: | Non-Customized |
Certification: | CE, FDA, EEC, ISO13485 |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Physical specifications | |
Screen: | 10.4 '' LCD Display Screen |
Suitable | Adult & Child |
Mode: | pneumatically powered and electrically controlled system |
Circuit | Breathing circuit integrated standards |
Flowmeters: |
5 Tubes Flowmeters: O2:0.1~10L/Min, N2O:0.1~10L/Min; Air: 0.1~10L / Min |
Technical Specifications: | |
safety valve | <12.5 kPa |
Respiratory Rate | 1~99bpm |
oxygen concentration in the mixed gas N2O/O2 |
> 21% |
Oxygen Flush: | 25~75 L/min |
PEEP: | 0 ~ 20 hPa |
Ptr: | -10 ~ 20 hPa |
IMV frequency: | 1 ~ 20 bpm |
I/E Ratio: | 8:1 ~ 1:10, Has the inverse ratio ventilation |
Tidal Volume | 0 ~ 1500 ML |
Inspiratory Plateau: | 0~1s |
O2 Concentration: | 21%~100% |
Maximum safety pressure: | ≤ 12.5 kPa |
Pressure limit range: | 0 ~ 6.0 kPa |
Airway pressure alarm: Audible and visual and with yellow and red color indicating |
Lower: 0.2kPa~5.0kPa; Upper: 0.3~6.0 kPa |
±0.2 kPa | |
Tidal volume alarm: Audible and visual and with yellow and red color indicating |
upper alarm: 50 to 2000ml, lower alarm: 0~1800ml |
Oxygen concentration alarm: Audible and visual and with yellow and red color indicating |
upper alarm: 21% ~100%; lower alarm:10%~80% |
Operating conditions | |
Ambient temperature: | 10 ~ 40oC |
Relative humidity: | no higher than 80 % |
Atmospheric pressure: | 860 hPa ~ 1060 hPa |
Power requirement: | ~220-240V, 50/60Hz, 40VA, to be well grounded. |
Attention: the AC power supply used for the anesthesia machine must be well grounded. |
|
Ambient temperature: | -15oC ~ +50oC |
Relative humidity: | no higher than 95 % |
Atmospheric pressure: | 86 kPa ~ 106 kPa. |
It should be stored in a room without corrosive gas and well ventilated |
|
packaging box | comply with the requirement of GB/T 15464 |
Oxygen Alarm |
It alarms when the oxygen supply from pipe or cylinders lower than 0.2MPa |
Ventilation Volume Alarm | Lower: 0~12L/Min; Up: 18L/ Min |
PACKAGE INCLUDED | |
QTY | NAME |
1 Unit | Main unit |
1 set | Patient Circuit |
1 pc | 5-tube flow meter |
2 pcs | vaporizer |
1 pc | Oxygen delivery tube |
1 pc | Air Delivery Tube |
1 set | Bellow ( Adult/ Child) |
1 set | Na lime tank |
1 set | Diaphragm electronic sensor |
1 set | Oxygen Regulator or central oxygen supply |
2 pcs | A leather bag ( Blue) |
1 pc | Y Pipe |
2 pcs | mask |
1 set | Oxygen probe |
1 set | Tools with the machine |
1 set | Scrubber |
1 set | User Manual (English Version) |
Optional | Patient Monitor |