• Cms8500 Patient Monitor
  • Cms8500 Patient Monitor
  • Cms8500 Patient Monitor
  • Cms8500 Patient Monitor
  • Cms8500 Patient Monitor
  • Cms8500 Patient Monitor

Cms8500 Patient Monitor

Customized: Customized
Certification: CE, FDA, EEC, ISO13485
Scale: Medium
Type: Health Care Intercom System
Brand Name: Rgw
Quality: High Quality
Customization:
Gold Member Since 2023

Suppliers with verified business licenses

Shanghai, China

Basic Info.

Model NO.
RGW-Z0891
After-Sale Service
Online Technical Support
Warranty Year
3 Years
Place of Origin
Shanghai, China
Instrument Classification
Class II
Safety Standard
GB/T18830-2009
Transport Package
Carton Box
Specification
N/M
Trademark
RGW
Origin
China
Production Capacity
10000PCS/Month

Product Description

 

Cms8500 Patient MonitorCms8500 Patient MonitorCms8500 Patient MonitorCms8500 Patient MonitorCms8500 Patient MonitorCms8500 Patient Monitor

 
CMS8500 Patient Monitor The monitor boasts a plethora of functions suitable for clinical monitoring of adults, pediatrics, and neonates. Users have the ability to select parameter configurations tailored to specific requirements. Powered by 100V-240V~, 50Hz/60Hz, the monitor is equipped with a 14" color TFT LCD display presenting real-time data and waveforms. The device can simultaneously display ten-channel waveforms and complete monitoring parameters while offering an optional 48mm thermal recorder. Additionally, the monitor can be wiredly connected to a central monitoring system to form a network monitoring system. This apparatus can monitor vital parameters, including ECG, RESP, NIBP, SpO, and dual-channel TEMP, among others. The parameter measurement module, display, and recorder are integrated into a single, compact, and portable device. Furthermore, its replaceable internal battery brings a great deal of convenience for patient mobility. Function: 14" high-definition touch screen design, easy and convenient to operate, elegant and concise in appearance. Independent physiological and technical alarm function, convenient for medical staff to quickly know patient's condition. Adopt high-performance processor, stable, reliable and fast to process information. Patient information can be rapidly entered, patient type (adult/neonate/pediatric) can be quickly switched, meets the requirements of different departments. Abundant analysis functions: 23 arrhythmia, full-lead ST-segment and pacing analysis; multiple calculation functions (such as calculation of drug concentration, titration table, hemodynamics, ventilation, oxygenation, renal function, etc.). With the functions of waveform freezing, holographic waveform storage and review. Automatic data storage in case of power failure. Built-in large-capacity detachable lithium battery, ensures uninterrupted monitoring. Fanless design, ensures no noise and low power consumption during working. Connect to Central Monitoring System developed by our company by WiFi/Wired, convenient to transmit patient's real-time information by mode, be applied to clinical monitoring, avoids affecting patient's rest, one-button switching, reduces the workload of medical staff. Performance: ECG Lead type: 3-lead: I, II, II 5-lead: l, II, Il, aVR, aVL, aVF, V 12-lead: l, ll, Il, aVR, aVL, aVF, V1, V2, V3, V4, V5, V6 Gain: 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV, 40mm/mV Scan speed: 6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s HR Measurement and alarm range: Adult: 15~300 bpm Pediatric/neonate: 15~350 bpm Resolution: 1 bpm Accuracy: ±1% or ±1bpm, whicheveris greater. ST-segment detection Measurement and alarm range: -2.0mV~+2.0 mV Accuracy: -0.8mV~+0.8mV: ±0.04mV or ±10%, whicheveris greater. Other range: unspecified Arrhythmia analysis: 23 kinds Pacemaker: yes RESP Measurement mode: impedance Respiration rate: Measurement range: 0 rpm~150 rpm Resolution: 1 rpm Accuracy: 7~150 rpm, ±2rpm or±2%, whicheveris greater; 0~6 rpm, unspecified Apnea alarm: 10~60s. Scan speed: 6.25mm/s, 12.5 mm/s, 25mm/s, 50mm/s. NIBP Measurement mode: Oscillometry Working mode: Manual/AUTO/Continuous/Order Measurementinterval in AUTO mode: 1 min, 2 min, 2.5 min, 3 min, 5 min, 10 min, 15 min, 20min, 30min, 1h, 1.5h, 2h, 3h, 4h, 8h Measurement period in Continuous mode: 5 minutes Static pressure Measurement range: 0mmHg~300 mmHg (0.0kPa~40kPa) Resolution: 1mmHg Cuff pressure accuracy: ±3mmHg Measurement accuracy: Maximal mean deviation: ±5 mmHg Maximal standard deviation: 8 mmHg Over-pressure protection: Adult mode: 297±3mmHg Pediatric mode: 260±3 mmHg Neonatal mode: 147±3mmHg SpO Measurement range: 0%~100 % Resolution: 1% Accuracy: 70%~100%, ±2%;0%~69%, unspecified PR Measurement and alarm range: 25~250 bpm Accuracy: ±2 bpm or±2%, whicheveris greater. TEMP Channel: dual-channel Measurement range: 0~50ºC Resolution: 0.1ºC Accuracy: ±0.1ºC CO Measurement mode: mainstream or sidestream CO measurement range: 0~150 mmHg Accuracy: 0~40mmHg: ±2mmHg; 41~70mmHg: ±5%; 71~100mmHg: ±8%; 101~150mmHg: ±10% AwRR measurement range: Sidestream: 2~120 rpm; Mainstream: 2~150 rpm. AwRR accuracy: ±1rpm Apnea alarm: yes IBP Channel: 2-channel (Expandable 4-channel) Label: ART, PA, CVP, RAP, LAP, ICP, P1, P2 Measurement and alarm range: -50~300 mmHg. Resolution: 1mmHg. Accuracy: ±2% or 1 mmHg, whicheveris greater. Power supply: 100V-240V~50Hz/60 Hz. Safety class: classl, defibrillation-proof type CF applied part. Waterproof degree: IPX2.
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now