• Medical Sicence Human Simulation
  • Medical Sicence Human Simulation
  • Medical Sicence Human Simulation
  • Medical Sicence Human Simulation
  • Medical Sicence Human Simulation
  • Medical Sicence Human Simulation

Medical Sicence Human Simulation

Brand Name: Rgw
Quality: High Quality
After-Sale Service: Online Technical Support
Warranty Year: 3 Years
Place of Origin: Shanghai, China
Instrument Classification: Class II
Customization:
Gold Member Since 2023

Suppliers with verified business licenses

Shanghai, China

Basic Info.

Model NO.
RGW-Z0818
Safety Standard
GB/T18830-2009
Transport Package
Carton Box
Specification
N/M
Trademark
RGW
Origin
China
Production Capacity
10000PCS/Month

Product Description

 
Medical Sicence Human SimulationMedical Sicence Human SimulationMedical Sicence Human SimulationMedical Sicence Human SimulationMedical Sicence Human SimulationMedical Sicence Human Simulation

Product Application

1. Simulating standard open airway ,Voice prompt
2. External breast compression: Digital display and alarm device ,Voice prompt .
(a) indicator light display of correct and wrong compression ; voice prompt of wrong compression;
(b) Intensity display of correct (at least 5cm) and wrong (less than 5cm) compression; Digital display of wrong compression and voice prompt .
3. Artificial respiration (inhalation): display device and alarm device
(a) Inhalation <500-600ml or > 600ml, wrong indicator light display and alarm prompting; inhalation between 500-600ml right indicator light display;
(b) Indicator light display open airway;
(c) Inhalation too quickly or too much result in air entering into stomach; indicator light display and alarm prompting.
4. Ratio of compression and artificial respiration: 30:2 (one or two person).
5. Operating cycle: one cycle includes five times of 30:2 ratio of compression and artificial respiration.
6. Operation frequency: at least 100 times per minute
7. Operation methods: exercise operation
8 .Operation thermal paper to print transcripts

9. Examination of pupil response: mydriasis and myosis
10. Examination of carotid response: pinch the pressure ball by hand and simulate carotid pulse
11. Working conditions: Input power is 110-240V

 
Adult
Children 1 to 8 years old
Baby
Open the airway
His head and chin lift method
Artificial respiration
2 Effective breathing (each lasting more than 1 second)
Respiratory rate
10-12 beats / minute         (  about 5 to 6 seconds to blow once)
10-12 beats / minute                ( about 3 to 5 seconds to blow once)
10-12 beats / minute                ( about 3 to 5 seconds to blow once)
Inspection cycle
Jin artery
Head arteries
Brachial artery
Pressing position
Sternal notch lower chest (chest xiphoid Department) two fingers on the middle part of the sternum or chest nipple cable median level
The next cross-refers to the connection nipple
Push mode
Two overlapping palm roots
A palm root overlapping / a palm roots
2 finger (thumb to ring the chest with both hands, two law)
Compression depth
At least 5cm
At least 3cm
At least 2cm
Pressing frequency
At least 100 times / min
Pressing ventilation ratio
30:2 (single or double)
30:2 / 15:2 or single / double
30:2 / 15:2 or single / double
Tidal volume
500ml ~ 600ml
Per kg / 8ml (about 150ml ~ 200ml)
30ml~50ml
CPR cycle
30 is pressed, the effective blowing two times five cycles CPR
AED
Conditions under AED device, please use the AED defibrillator once, then 5 cycles CPR.
Not recommended

 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now